Altech Search
   

UL Ground Fault Equipment Protectors

Altech Industrial Enclosures

Click to Download Catalog

Altech has the most complete line of UL Ground Fault EQUIPMENt Protection products in the industry.


The selection includes
(Click title to go to that section)

Application Examples

  • Wire insulation “Surveillance”
  • Motor winding failure detection
  • Production Equipment which can’t afford uncontrolled shutdown
  • Pre-short circuit detection
Pump Application

Industries

  • Chemical Plants
  • Refineries
  • Waste Water Treatment Plants
  • Semiconductor Facilitie
  • Pharmaceutical Plants
  • Plants near water (salt water especially)

Ground Fault Request Form
& Specification pages are below.

Name Email
Company Address
Title Address 2nd
City State
Zip Code Phone
Message
     

Individual Specifications Sheets
including wiring diagram examples
& CAD Files

UL 489

GFL Series (5A - 40A)
10kA UL489 Listed Branch Circuit Breaker with
Equipment Ground Fault Protection (RCBO)

UL489

The UL 489 Branch Circuit with Ground Fault Relay is the 1st in the industry! Since it includes a UL 489 Branch Circuit Protector, in many cases there is no need for upstream circuit protection. It comes in 1+N pole, 2 pole and 2 pole +N configurations at 240V AC, 120/240V AC. It has a rated current of 5 - 40A. It also has a Rated Short Circuit Interrupt Capacity of 10kA and comes in Overload tripping curves B, C and D. The Rated Frequency is 50/60Hz.

  Series / Pole / Trip / mA

GFL Series - 1 Pole+N

 

GFL 2 Pole

GFL-1P+N-B-10mA.pdf
GFL-1P+N-B-30mA.pdf
GFL-1P+N-B-100mA.pdf
GFL-1P+N-B-300mA.pdf
GFL-1P+N-C-10mA.pdf
GFL-1P+N-C-30mA.pdf
GFL-1P+N-C-100mA.pdf
GFL-1P+N-C-300mA.pdf
GFL-1P+N-D-10mA.pdf
GFL-1P+N-D-30mA.pdf
GFL-1P+N-D-100mA.pdf
GFL-1P+N-D-300mA.pdf

GFL DWG
GFL STEP


  Series / Pole / Trip / mA

GFL Series - 2 Pole

GFL 2 Pole


GFL-2P+B-10mA.pdf
GFL-2P+B-30mA.pdf
GFL-2P+B-100mA.pdf
GFL-2P+B-300mA.pdf
GFL-2P+C-10mA.pdf
GFL-2P+C-30mA.pdf
GFL-2P+C-100mA.pdf
GFL-2P+C-300mA.pdf
GFL-2P+D-10mA.pdf
GFL-2P+D-30mA.pdf
GFL-2P+D-100mA.pdf
GFL-2P+D-300mA.pdf

GFL DWG
GFL STEP


  Series / Pole / Trip / mA

GFL Series - 2 Pole + N

GFL 2 Pole

GFL-2P+N-B-10mA.pdf
GFL-2P+N-B-30mA.pdf
GFL-2P+N-B-100mA.pdf
GFL-2P+N-B-300mA.pdf
GFL-2P+N-C-10mA.pdf
GFL-2P+N-C-30mA.pdf
GFL-2P+N-C-100mA.pdf
GFL-2P+N-C-300mA.pdf
GFL-2P+N-D-10mA.pdf
GFL-2P+N-D-30mA.pdf
GFL-2P+N-D-100mA.pdf
GFL-2P+N-D-300mA.pdf

GFL DWG
GFL STEP

Back to top.


GF Series (up to 63A)
480Y/277V AC Ground Fault Sensing
and Relaying Device (RCCB)

UL1053/UL1077

The UL 1053 approved device comes in 1 pole + N and 3 pole + N at 277V AC, 480Y/277V AC. It has a Rated Current of 25, 40 and 63A. It also has a Rated Short Circuit Withstand Capacity of 10kA and a Rated Frequency of 50/60Hz.

The GF Series of Equipment Ground Fault Protection Relays (Earth Leakage Protection) is providing ground fault (residual current) as well as pulsating DC ground fault protection for circuits with loads up to 63A.

  Series / Pole / Trip / mA

GF Series - 1 Pole+N

GFL 2 Pole

GF-1P+N-10mA.pdf
GF-1P+N-30mA.pdf
GF-1P+N-100mA.pdf
GF-1P+N-300mA.pdf

GF DWG
GF STEP


  Series / Pole / Trip / mA

GF Series - 3 Pole+N

GFL 2 Pole

GF-3P+N-30mA.pdf
GF-3P+N-100mA.pdf
GF-3P+N-300mA.pdf

GF DWG
GF STEP

Back to top.


GFR Series (5A - 40A)
480Y/277V AC Ground Fault Relay
with Overload Protection (RCBO)

UL1053/UL1077

The UL 1077/1053 device comes in 1 pole + N and 3 pole + N at 277V AC, 480Y/277V AC. Rated Current ranges from 5 - 40A. It also has a Rated Short Circuit Withstand Capacity of 10kA, and comes in Overload tripping curves B, C and D. The Rated Frequency is 50/60Hz.

The GFR Series is a combined Equipment Ground Fault Relay and Supplementary Protector (RCBO) is designed to provide protection against overloads and AC ground faults (residual current faults) as well as pulsating DC ground faults.

  Series / Pole / Trip / mA

GFR Series - 1 Pole+N

GFL 2 Pole

GFR-1P+N-B-10mA.pdf
GFR-1P+N-B-30mA.pdf
GFR-1P+N-B-100mA.pdf
GFR-1P+N-B-300mA.pdf
GFR-1P+N-C-10mA.pdf
GFR-1P+N-C-30mA.pdf
GFR-1P+N-C-100mA.pdf
GFR-1P+N-C-300mA.pdf
GFR-1P+N-D-10mA.pdf
GFR-1P+N-D-30mA.pdf
GFR-1P+N-D-100mA.pdf
GFR-1P+N-D-300mA.pdf

GFR DWG
GFR STEP


  Series / Pole / Trip / mA

GFR Series - 3 Pole+N

GFL 2 Pole

GFR-3P+N-B-30mA.pdf
GFR-3P+N-B-100mA.pdf
GFR-3P+N-B-300mA.pdf
GFR-3P+N-C-30mA.pdf
GFR-3P+N-C-100mA.pdf
GFR-3P+N-C-300mA.pdf
GFR-3P+N-D-30mA.pdf
GFR-3P+N-D-100mA.pdf
GFR-3P+N-D-300mA.pdf

GFR DWG
GFR STEP

Back to top.


For more information contact Altech at:
908-806-9400 • 908-806-9490 (FAX) • info@altechcorp.com • 35 Royal Road, Flemington, NJ 08822