L - Series
UL 489 Miniature Molded Case
Circuit Breakers
- Available in AC and DC models
- DIN Rail Mounted
- 17.5mm width
- Thermal Magnetic
- 240V, 480Y/277V AC, 50/60Hz
- 125VDC (1 pole); 250VDC (2pole)
- 10kA Short Circuit
Interrupting Capacity
- Positive Trip indicator
(Green - off/tripped, Red - on)
- HACR Type 40°C
- Line/Load reversible
|
|
UL(AC),
DL(DC) - Series
UL489 Miniature Molded Case
Circuit Breakers
- Available in AC and DC models
- DIN Rail Mounted
- 17.5mm width
- Thermal Magnetic
- 240V, 480Y/277V AC, 50/60Hz
- 125V DC (1 pole); 250V DC (2pole)
- 10kA Short Circuit
Interrupting Capacity
- HACR Type 40°C
- Line/Load reversible
|
|
M - Series
Manual Motor Controller
with Disconnecting Mean
UL508 Listed Circuit Breakers
- DIN Rail Mounted
- 17.5mm width per pole
- Thermal Magnetic
- 480Y/277V AC, 50/60Hz
- 10kA Short Circuit Withstand Capacity
- Line / Load Reversable
- Positive Trip indicator (Green - off/tripped, Red - on)
|
|
UM - Series
UL508 Listed Manual Motor Controllers
“Suitable as Motor Disconnect”
- DIN Rail Mounted
- 17.5mm width per pole
- Thermal Magnetic
- 0.3-60A / 480Y/277V AC, 50/60Hz
- 10kA Short Circuit
Withstand Capacity
- Applications Include:
- AC Motor Starting, Across the Line
- AC General Use
- AC Resistance
- AC Discharge Lamps (Ballast)
- AC Incandescent Lamps (Tungsten)
|
|
R - Series
UL1077 Recognized Supplementary Protectors
- DIN Rail Mounted
- 17.5mm width per pole
- Thermal Magnetic
- 480Y/277V AC, 50/60Hz
- 10kA Short Circuit
Withstand Capacity
- Positive Trip indicator
(Green - off/tripped, Red - on)
- Applications (on the load side
of Branch Circuit Protection)
include: Sensitive Electronics,
Power Supplies, Appliance
circuits, etc.
|
|
UR - Series
UL1077 Recognized Supplementary Protector
- DIN Rail Mounted
- 17.5mm width per pole
- Thermal Magnetic
- 0.3-60A / 480Y/277V AC, 50/60Hz
- 10kA Short Circuit
Withstand Capacity
- Applications (on the load side
of Branch Circuit Protection)
include: Sensitive Electronics,
Power Supplies, Appliance
circuits, etc.
|
|
|
UL489
Busbar System
|
|
Cuttable UL489
Busbar System
- Ratings of up to 115A
- UL listed for use with most competitor’s UL 489 Miniature Circuit Breakers
- 30% Installation time savings
- Panel space savings
- Reduced maintenance
- High electrical ratings
|
|
Cuttable UL508 / UL1077
Busbar System
|
|
|
GFL Series (5A - 40A)
10kA UL489 Listed Branch Circuit Breaker with
Equipment Ground Fault Protection (RCBO)
The UL 489 Branch Circuit with Ground Fault Relay is the 1st in the industry! Since it includes a UL 489 Branch Circuit Protector, in many cases there is no need for upstream circuit protection. It comes in 1+N pole, 2 pole and 2 pole +N configurations at 240V AC, 120/240V AC. It has a rated current of 5 - 40A. It also has a Rated Short Circuit Interrupt Capacity of 10kA and comes in Overload tripping curves B, C and D. The Rated Frequency is 50/60Hz. |
|
GF Series (up to 63A)
480Y/277V AC Ground Fault Sensing
and Relaying Device (RCCB)
The UL 1053 approved device comes in 1 pole + N and 3 pole + N at 277V AC, 480Y/277V AC. It has a Rated Current of 25, 40 and 63A. It also has a Rated Short Circuit Withstand Capacity of 10kA and a Rated Frequency of 50/60Hz. |
|
GFR Series (5A - 40A)
480Y/277V AC Ground Fault Relay
with Overload Protection (RCBO)
The UL 1077/1053 device comes in 1 pole + N and 3 pole + N at 277V AC, 480Y/277V AC. Rated Current ranges from 5 - 40A. It also has a Rated Short Circuit Withstand Capacity of 10kA, and comes in Overload tripping curves B, C and D. The Rated Frequency is 50/60Hz. |
|
DFS - Series
RCCB Earth Leakage Circuit Breakers
Compact DIN rail mount RCCB Earth Leakage Circuit Breakers detect and interrupt ground faults. They are VDE approved for the European system of protecting people, animals, equipment and property from dangerous line-to-ground and shock hazard currents. |
|
MA - Series
Three Phase Adjustable Trip
Miniature Circuit Breakers/ Manual Motor Controllers
The MA was designed to handle the high inrush loads of 3 phase transformers, power supplies, motors, etc. The MA protects wiring and equipment from damage caused by the three major classes of overcurrent, yet greatly reduces the number of nuisance trips in high starting and inrush current circuits. |
|
MS - Series
Three Phase Adjustable Trip
Economy Manual Motor Controllers
With its high breaking capacity and current limitation the MS Manual Motor Controllers provide optimum protection for electrical motors as well as for other consumer units up to 25 amps. They are equipped with phase failure sensitivity, isolating and main switch functions. 13 ranges cover nominal rated currents from 0.1 up to 25 amps. |
|
TR - Series
UL1077 Recognized
Supplementary Protector/
Circuit Breaker for Equipment
Electrical Ratings: 0.5-16.0A / 240V AC, 50/60Hz, 32V DC / 24V DC (VDE)
Applications:
Protection of Control Transformers, UPS, Power strips, Solenoids etc., against damage due to
overload conditions. |
|